SPE columns for H53-method analysis
SPE COLUMN FOR H53 METHOD
Elufix™- Columns
Elufix™ glass columns have been developed for use in sample preparation for the determination of the mineral oil hydrocarbon index (H53 method) according to DIN EN ISO 9377-2. They are also suitable for CHC soil analysis according to DIN EN ISO 16703 and 14039.
For samples where conditioning is not necessary, the specially developed TINY version can be used. Our high-quality TINY glass columns are ideal for downscaling methods to smaller volumes. The specially developed column outlet allows direct elution into a GC vial. The TINY columns are supplied in an ALU pendulum packaging. This minimises the entry of blank values, which makes conditioning of the columns obsolete. The filling quantity of these columns can be individually adapted to the needs of the user.
- Home
- Products
- SPE Consumables and Accessoires
- SPE Columns for H53 Method Analysis
READY-TO-USE COLUMNS
Standard Elufix™ Columns
Made of glass for method H53, batch certification enclosed, qualification test and result performance according to EN ISO 9377-2.
Filling material: 2 g Florisil®
(150 - 250 µm)
& 2 g anhydrous sodium sulfate
Quantity: 50 pcs
Filling material: 1 g Florisil®
(150 - 250 µm)
& 1 g anhydrous sodium sulfate
Quantity: 50 pcs
Filling material: 4 g Florisil®
(150 - 250 µm)
& 2 g anhydrous sodium sulfate
Quantity: 50 pcs
Filling material: 2 g Florisil®
(150 - 250 µm)
& 2 g anhydrous sodium sulfate
Quantity: 50 pcs
With Luer outlet
READY-TO-USE COLUMNS
Elufix™ TINY Columns
Made of glass for method H53, batch certification enclosed, suitability test and result presentation according to EN ISO 9377-2, suitable and fitting in combination with GC-Vial.
Filling material: 1,0 g Florisil® (150 - 250 µm)
Length: 55 mm
Outer diameter: 17 mm
Outer diameter outlet pin: 4 mm
Nominal content: 5 mL
Quantity: will be delivered in reusable Alumina boxes (shuttle boxes) 1820 pcs
P/N 9315
Other fill quantities, also in combination with sodium sulphate, are available on request.
RACK FOR 20 GC-VIALS
Use in Combination with Elufix™ TINY Columns
Two of the Elufix™ TINY columns supplied in strips of 10 can be placed on the GC-vials. The rack gives the necessary stability to the work step and enables quick processing without additional equipment. The rack holds 2 strips of TINY columns on 20 GC vials (not included in 20227).
P/N 20227
1. Insert vials in TINY-GC-Vial rack
2. Place TINY column strips on top of the vials
3. Apply sample
4. Remove TINY column strips from rack. Filled vials can be transferred for subsequent analysis